CAB Extraflex 11-12 O.R. PVC-PUR

APPLICATION :
Supply of Indramat brushless motors. Trailing chains. Dynamic applications. Robotics.
TECHNICAL CHARACTERISTICS
Service Voltage :
450/750V power conductors 250V signal conductors
Test Voltage :
3000V power conductors 1000V signal conductors
Insulation Resistance :
>/= 100 Mohm x km (at 20oC)
Temperature :
service from -10oC to + 80oC storage from -30oC to + 80oC
Conductor Stranding :
extra-flexible class 6 acc. Standards VDE 0295 - IEC 228 - CEI 20-29
Primary Insulation :
power: Special PVC compound signal: PETP polyester terephtalate
Conductors Identification :
power: black numbered 1-2-3 + YE/GRN signal: black numbred 5-6-7-8
EMC shield (for type 12) :
on total: tinned copper braid covering >/= 85% signal: alum/pol + tinned copper braid
Taping :
special tape
Jacket :
special PUR compound abrasion-free colour orange RAL 2003
Min. Bending Radius:
10 x external cable diameter
Translation Speed :
180 m/min.
Max. Acceleration :
7 m/s2

Size&Dimensions
Reference Standards :
VDE 0472-804 B - IEC 332.1 - CEI 20 - 35 for flame resistance VDE 0472-803-B for ASTM2 oil resistance CNOMO E.03.40.150 N - NFT 46.013 for resistance to industrial oils VDE 0472-815 halogen-free version

website: www.caledonian-cables.com

email: sales@caledonian-cables.com